Control
1. Disconnect the negative cable from the battery.
2. Additional resistances are located in the left part of a motor compartment.
3. Locate the resistance connector along the wires and break the electrical contact.
4. Measure the resistance between terminals A and each of the four injector power terminals. Resistance should be in the range of 5-7 ohms.
Pic. 16.4 Connector and contacts of additional resistances. A - main power terminal
5. If the measured resistance is out of range, replace it.
Replacement
6. Turn away bolts of fastening of the block of resistances from the case and remove the block.