Contents: Replacement ⇊ Trial ⇊
Replacement
1. Remove the sun sensor from the instrument panel and disconnect the 2K connector.
Note: Be careful not to damage the panel.

2. The installation procedure is the reverse of the removal procedure.
Trial
Turn on the ignition (ON II). Measure the voltage: probe (+) to pin # 1, probe (-) to pin #2 of the 2K connector. The voltage must be:
- 3.7±0.2V or more when the sensor is out of direct sunlight.
- 3.6±0.2V or less when the sensor is under direct light.
Note: The voltage will not change under artificial light or fluorescent light

The text was taken from the website HONDABOOK.ru