2. Disconnect the 10-terminal block (10P) connector from the lock cylinder switch.
3. Check the connection between the terminals.
There should be a connection between terminals #8 [7] and #5 [10] when the door lock cylinder switch is in the "LOCK" position.
There should be no connection between terminals #8 [7] and #5 [10] when the door lock cylinder switch is in the neutral or unlocked position.
![]() |
![]() |
There should be a connection between terminals #9 [6] and #5 [10] when the door lock cylinder switch is in the unlocked position" ("UNLOCK").
There should be no connection between terminals #9 [6] and #5 [10] when the door lock cylinder switch is in the neutral or locked position.
[]: vehicle with PRK.
4. If the connection is not as specified, replace the door lock cylinder assembly.