Major renovation
Replacing the air flow control cable
Note: LHD type is shown, RHD type is similar.
1. Cut the inner cable from the cable release lever side, then remove both pieces of the inner cable.
2. Using a sharp knife, cut completely through the end of the cable housing in two places.
3. Slide most of the cable housing out of the cable retainer, being careful not to damage the cable stops.
4. Carefully remove the cut pieces of the cable housing using a small flat-tip screwdriver.
5. Attach the end of the new air control cable to the temperature control lever, then push the cable housing into the cable retainer; it will not lock in place.
Note: After assembly, check that the temperature control lever moves smoothly from right to left.