Withdrawal
1. Disconnect the battery from the ground.
2. Disconnect the wiring from the master cylinder.
3. Remove the fluid from the master cylinder, disconnect the tubes.
4. Remove the main cylinder from the amplifier.
5. Disconnect from the amplifier vacuum hoses.
6. Unsplint and remove the brake pedal axle.
7. Turn away bolts of fastening and remove the amplifier.
Installation
8. Installation is carried out in the reverse order.
9. Fill cylinder with DOT 3 or DOT 4 brake fluid and bleed air.