2. Disconnect the starter cable from the B terminal on the solenoid, then disconnect the BLACK/WHITE wire from the S terminal.
1. 10x1.25 mm, 44 Nm (4.5 kgf/m); 2. 10 x 1.25 mm, 44 Nm (4.5 kgf/m); 3. Black and white wire; 4. Fastening nut, terminal B, 9 Nm (0.9 kgf/m); 5. Starter cable
3. Turn off two bolts fixing a starter, then remove a starter.
4. Installation is carried out in the reverse order of removal. When connecting the starter cable, make sure that the crimped side of the cable lug is facing out.
1. Crimp side of cable lug; 2. Nut; 3. Terminal
5. Connect the positive and negative cables to the battery.