Testing the signal at the controller input
Note: The control unit is built into the instrument panel light controller.
1. Remove the switch panel from the instrument panel.
2. Disconnect the 3-pin connector from the controller.
1. 3-PIN CONNECTOR
2. RED
3. BLACK AND RED
4. BLACK
5. Female connector on the harness side
6. INSTRUMENT PANEL LIGHTING CONTROL
3. Press the controller from behind the panel and remove it.
4. Check the connector contacts and make sure they provide reliable contact.
- If contacts are bent, loose or corroded, repair the defects and retest the system.
- If the contacts appear to be OK, perform the following tests on the connector (table).
- If any of the tests indicate a problem, find and correct the cause, then retest the system.
- If the test at the regulator input shows normal, the regulator must be faulty, replace it.
[Material obtained from the website «hondabook»]