Note: Installation is carried out in the reverse order of removal.
1. Remove the refrigerant from the system.
2. Remove the front bumper.
3. Loosen the bolt and nut and disconnect the condenser inlet and outlet pipes. Remove the sealing rings and install plugs on the open ends of the pipes and fittings.
- Tightening torque - 9.8 Nm
Right hand drive models.
Left-hand drive models.
4. Unscrew the bolts of the two upper brackets of the condenser and remove it upwards.
Right hand drive models.
1 - condenser fan connector,
2 - upper brackets of the condenser,
3 - capacitor.
Left-hand drive models.
1 - capacitor,
2 - upper brackets of the condenser.