2. Disconnect the 2-pin connector from the lock actuator assembly.
![]() |
![]() |
3. Apply battery voltage to the terminals as shown below and check that the rod moves to LOCK and UNLOCK side.
Caution: When applying voltage from the battery to the drive, briefly connect the wire to the (-) terminal of the battery. If voltage is applied for a long time, the drive may be damaged.