1. Turn the ignition key to the ON position (II), set the air conditioner control to the maximum cooling position (18°С) and turn the ignition key to the OFF position.
2. Attach the cable ring to the link pin, place the cable on the stopper and secure with the clamp.
3. Move the water valve lever in the direction of the arrow.
4. Attach the cable ring to the lever pin, push the lever in the direction of the arrow, and secure the cable with the clamp.