2. Connect the (+) wire from the battery to terminal #1 of the connector, and the (-) wire to terminal N92, and make sure that the electric motor switches to the HOT (heating) position. If you connect the wires the other way around, the electric motor should switch to the COOL (cooling) position.
3. Measure the resistance between contacts No.5 and No.7.

- Standard resistance: 4.2-7.8kΩ
4. Measure the resistance between contacts No.3 and No.7.
Standard resistance:
- In the maximum heating position (MAX HOT): 3.52-6.55 kΩ
- In the maximum cooling position (MAX COOL): 0.85-1.09 kΩ
5. If the electric motor does not work as described in point 2, remove it and check the operation of the traction.
6. If the rod moves freely, replace the mixing flap motor.